
FireSAFE 4X
- 4-Hour Fire-Rated
- 8 ft x 40 ft
- 57 Barrels
- 55 Gal Storage Drums
- 228 Square Feet storage
Compliant storage and rental solutions for Methyl Acrylate, Inhibited (C₃H₆O₂). EPA, OSHA, and NFPA guidance for containment, segregation, and fire protection — with rental buildings matched to this material.
Methyl acetate is a volatile solvent. It is therefore used in fast-drying paints and for the manufacture of celluloid adhesives from waste film. Methyl acetate is often used in lacquer solutions to lower the viscosity. Methyl acetate may also be used in perfumery and in dye manufacture.
Acute oral toxicity Category 4 Acute dermal toxicity Category 4 Acute Inhalation Toxicity - Dusts and Mists Category 3 Skin Corrosion/Irritation Category 2 Serious Eye Damage/Eye Irritation Category 2 Skin Sensitization Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system.
Dry Chemical fire suppression is recommended for Methyl Acrylate, Inhibited
Guidance: Dry Chemical fire suppression is generally recommended for Methyl Acrylate, inhibited (C₃H₆O₂). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Additional extinguishing notes: Water spray. Carbon dioxide (CO 2). Dry chemical. Chemical foam. Water mist maybeusedto cool closed containers.
Always confirm extinguishing agents against the manufacturer SDS and your authority having jurisdiction before specifying a rental building fire-suppression package.
Compliant storage and rental solutions for Methyl Acrylate, inhibited should account for its listed hazards (Flammable Liquids Category 2), climate control needs (Ambient), and segregation requirements. Methyl Acetate is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE).
Review NFPA 30 flammable liquid storage requirements and Fire-rated chemical storage rental when designing fire rating, containment, and building selection.
Properties: Melting Point/Range -75 °C / -103 °F Boiling Point/Range 80 °C / 176 °F @ 760 mmHg Flash Point -3 °C / 26.6 °F Evaporation Rate No information available Flammability (solid,gas) Not applicable Flammability or explosive limits Upper 25% Lower 2.8% Vapor Pressure No information available
Matched to this chemical
Fire rating, footprint, and containment options from the US Hazmat Rentals fleet — sized for compliant chemical storage.



Material handling
US Hazmat Rentals buildings are designed around the primary storage formats teams use in the field — each path opens the matching storage solution on ushazmatrentals.com.

Large-volume tote storage with forklift-ready handling inside compliant buildings.
Explore solution
Drum and pallet-adjacent workflows sized for secondary containment and segregation.
Explore solution
Pallet-in, pallet-out layouts for packaged chemicals and rack-ready inventory.
Explore solution
Locker and cabinet-scale storage for cans, jars, and other small-format chemicals.
Explore solutionWe have solutions designed for your workflow process needs.
Store Methyl Acrylate, inhibited in EPA-, OSHA-, and NFPA-compliant containment suited to its hazards (Flammable Liquids Category 2). Climate range guidance: Ambient. Compatibility notes: Methyl Acetate is not compatible with OXIDIZING AGENTS (such as PERCHLORATES, PEROXIDES, PERMANGANATES, CHLORATES, NITRATES, CHLORINE, BROMINE and FLUORINE); STRONG ACIDS (such as HYDROCHLORIC, SULFURIC and NITRIC); and STRONG BASES (such as SODIUM HYDROXIDE and POTASSIUM HYDROXIDE). US Hazmat Rentals provides compliant chemical storage buildings available for rental.
Yes — Methyl Acrylate, inhibited is flagged as a flammable hazard in this database (Yes). Flash point: -3 °C / 26.6 °F. Use fire-rated storage and follow NFPA 30 / applicable flammable-liquid rules where they apply.
Methyl Acrylate, inhibited is listed as: Flammable Liquids Category 2. Acute oral toxicity Category 4 Acute dermal toxicity Category 4 Acute Inhalation Toxicity - Dusts and Mists Category 3 Skin Corrosion/Irritation Category 2 Serious Eye Damage/Eye Irritation Category 2 Skin Sensitization Category 1 Specific target organ toxicity (single exposure) Category 3 Target Organs - Respiratory system.
Dry Chemical fire suppression is generally recommended for Methyl Acrylate, inhibited (C₃H₆O₂). *Please consult your raw material manufacturer's safety data sheet (SDS) and your local authority having jurisdiction to verify the most adequate fire suppression extinguisher for your specific storage or use.
Yes. US Hazmat Rentals offers EPA-, OSHA-, and NFPA-compliant chemical storage buildings and containment that can be matched to Methyl Acrylate, inhibited. Request sizing and compliance guidance at https://ushazmatrentals.com/chemical-storage-quote-request/.